Applicable
Throughout the Cooperative’s service area for qualifying members in accordance with the Cooperative’s membership agreement, Bylaws, policies, regulations, and the Conditions of Service set forth herein, as well as applicable Rules of the Wyoming Public Service Commission.
Available
To all members located adjacent to the Cooperative’s service area with types of usage involved to generate power at utility scale.
Type of Service
Single-phase, and three-phase where available, 60 hertz, at available secondary or primary voltage.
Monthly Rate
Local Distribution Service
Grid Access Charge |
$120.00 / month |
Delivery Charge |
$0.00663 / kW - NCP |
Peak Capacity Charge |
$8.00 / NCP kW |
Transmission Service
Delivery Charge |
$0 / CP kW |
Peak Capacity Charge |
$9.72 / CP kW |
Power Generation Service
Energy Production Charge |
$0.04496 / kWh |
Peak Capacity Charge |
$10.96 / CP kW |
Bundled kWh and kW rates (for informational purposes only)
All kWhs |
$0.05159 / kWh |
Peak kW – Transmission and Generation |
$20.68 / CP kW |
Peak kW - Distribution |
$8.00 / NCP kW |
Adder
If a member elects to incur an additional charge for purchase of “Renewable Energy” the charge will be $0.003 per subscribed kWh not to exceed total monthly usage.
Tariff Rate Rider
This rate schedule is subject to the Tariff Rate Rider set forth on Sheet Nos. 79, 81, 81a, and 81b.
Minimum Monthly Charge
The minimum charge shall be the highest of the following:
-
The minimum charge specified in the contract for service, or
-
A charge of $0.75 per kVA of installed transformer capacity.
-
The monthly access charge.
Determination of Billing Demand (non-coincident peak demand)
The billing demand shall be the maximum non-coincident kilowatt demand established by the member for any period of fifteen consecutive minutes during the month for which the bill is rendered, as indicated or recorded by a demand meter and adjusted for power factor as follows.
Power Factor Adjustment
The member agrees to maintain unity power factor as nearly as practicable. Demand charges will be adjusted for members with 50 kW or more of measured demand to correct for average power factor lower than 95% and may be so adjusted for members if and when the Cooperative deems necessary. Such adjustments will be made by increasing the measured demand 1% for each 1% by which the average power factor is less than 95% lagging.
Determination of Bill Demand (coincident peak demand)
The billing demand shall be the maximum kilowatt demand established by the member for any period of fifteen consecutive minutes (between 1:00 p.m. and 9:00 p.m.) during the month for which the bill is rendered, as indicated or recorded by a demand meter (except for Sundays).
Conditions of Service
-
The Cooperative will read the meters on a monthly basis.
-
The service contract may be cancelled by agreement of either parties. If the contract is cancelled, the member is no longer qualified to receive service under this service tariff at that location for twelve months.
-
The member, prior to being signed up on this service tariff, will be required to be current with its billing.